Number of arms | 2 (top surface × 2) |
Compatible probes | 1172 series, CP1072 series |
Number of test steps | 999,999 steps |
Test parameters and measurement ranges | Resistance measurement : | 40.00 μΩ to 40.00 MΩ |
| Insulation measurement : | 1.000 kΩ to 500.0 MΩ |
| Capacitance measurement : | 100.0 fF to 10.00 μF |
| Leakage current measurement : | 1.000 μA to 10.00 mA |
| High-voltage resistance measurement : | 1.000 kΩ to 500.0 MΩ |
| Capacitor insulation measurement : | 1.000 kΩ to 10.00 MΩ |
| Open measurement : | 4.000 Ω to 4.000 MΩ |
| Short measurement : | 400.0 mΩ to 40.00 kΩ |
Judgment range | -99.9% to +999.9% or absolute value |
Minimum pad pitch | 40 μm (with CP1075-09) |
Minimum pad size | 10 μm (with CP1075-09) |
Measurement speed | Max. 100 points/sec. (0.1 mm movements, 2-arm simultaneous probing, capacitance measurement) |
Testable boards | 50 mm (1.97 in) W × 50 mm (1.97 in) D to 610 mm (24.02 in) W × 510 mm (20.08 in) D, Thickness 0.1 mm (0.004 in) to 3.2 mm (0.13 in) |
Maximum testable area | 610 mm (24.02 in) W × 510 mm (20.08 in) D |
Power supply | 200 V, 220 V, 230 V, 240 V AC single phase (specify at time of order), 50 Hz/ 60 Hz, Maximum power consumption: 3 kVA |
Dimensions and mass | 1303 mm (51.30 in) W × 1194 mm (47.01 in) H × 1167 mm (45.94 in) D (excluding protruding parts), 900 kg (31746 oz) |