Rated current | 200 A AC/DC |
Max. allowable input | 400 A rms (requires derating) |
Frequency characteristics | Amplitude: DC to 500 kHz Phase: DC to 300 kHz |
Amplitude and Phase accuracy | DC ±0.05 % rdg. ±0.01 % f.s. (Phase: Not defined) 16 Hz ≤ f ≤ 400 Hz ±0.05 % rdg. ±0.01 % f.s. (Phase: ±0.2°) Defined to 500 kHz |
Output voltage | 2 V /rated current value (This device outputs AC+DC voltage via the Sensor Unit) |
Max. rated voltage to earth | AC/DC 1000 V (50/60 Hz, CAT III ) |
Core diameter | φ 24 mm (0.94 in) |
Operating temperature, humidity | -30°C to +85°C (-22°F to 185°F), 80% RH or less (with no condensation) |
Power supply | Power suppled via the Power Analyzer PW8001, PW6001, PW3390, Sensor Unit CT9555, CT9556, CT9557, or 3CH CURRENT UNIT U8977 |
Power consumption | 6 VA max. (at 200 A/55 Hz, ±12 V power requirement) |
Dimensions and mass | 70 mm (2.76 in)W × 100 mm (3.94 in)H × 53 mm (2.09 in)D, 350 g (12.3 oz), cord length: 3 m (9.84 ft) |
Included accessories | Instruction manual ×1, Mark bands ×6 |