Rated current | 2000 A AC/DC |
Max. allowable input | Within the derating range, (within the specified range up to ±3200 Apeak ) |
Frequency characteristics | Amplitude: DC to 1 MHz, Phase: DC to 700 kHz |
Basic accuracy | (DC, 45 Hz ≤ f ≤ 66 Hz) Amplitude: ±0.04 % rdg. ±0.008 % f.s., Phase: ±0.08° |
Output voltage rate | 1 mV / A rated (This device outputs AC+DC voltage via the Sensor Unit) |
Max. rated voltage to earth | 1000 V AC/DC (50/60 Hz, CAT III ) |
Core diameter | φ 80 mm (3.15 in) |
Operating temperature, humidity | -40°C to +85°C (-40°F to 185°F), 80% RH or less (with no condensation) |
Power supply | Power suppled via the Power Analyzer PW8001, PW6001, PW3390, Sensor Unit CT9555, CT9556, CT9557, or 3CH CURRENT UNIT U8977 |
Max. rated power | 9.5 VA max. (at 2000 A/55 Hz, ±12 V power requirement) |
Dimensions and mass | 229 mm (9.02 in)W × 232 mm (9.13 in)H × 112 mm (4.41 in)D, CT6877A: 5 kg (176.4 oz), cable length 3 m (9.84 ft), CT6877A-1: 5.3 kg (186.9 oz), cable length 10 m (32.81 ft) |
Included accessories | Instruction Manual ×1, Mark bands ×6, Operating Precautions ×1 |